Profinet Bus IO Temperature Acquisition Module
Profinet Distributed Remote Io Module Supports For Siemens 200 Smart S7-1200 S7-1500 Digital Analog Models Support Profnet Modbus
Protocol | Profinet,Modbus TCP |
Network Port | 3 *100M ports, switch function |
485 Gateway | 2 channels, support 485 to PROFINET function |
Terminal | Quick connect terminal |
Digital Input | PNP/NPN auto-adaptation |
Digital Output | PNP 0.5A, |
Analog Current | 0-20mA:0-20000/4-20mA:4000-20000 |
Analog Voltage | 0-10V:0-10000 |
Analog Accuracy | 1/1000 |
Temperature Thermal Resistance | PT100/PT1000,accuracy±0.1° |
Temperature Thermocouple | B/J/K/R/S/N ,accuracy±0.1° |
Dimensions | 45x108x125mm(W x D x H) with terminal rails |
Working Temperature | -20-50° |
Power Supply | 24V |
Material | Metal |
Installation method | Guide rail |
PROFINET Distributed IO Model
Digital Input | Digital Output 0.5A | Analog Input | Analog Output | Temperature RTD/RTC | 485 Gateway | Price | |
16 | 16 Transistors | – | – | – | 2 | ||
X | 32 Transistors PNP | – | – | – | 2 | ||
32 | – | – | – | – | 2 | ||
8 | 8 | 8 | 4 | – | 2 | ||
HJ5209A | – | – | 8 | – | – | 2 | |
HJ5209B | – | – | 8 | 8 | – | 2 | |
HJ5209C | – | – | 16 | – | – | 2 | |
HJ5209D | – | – | 8 | – | 8 | 2 | |
HJ5209H | – | – | – | 8 | – | 2 | |
HJ5209Q | – | – | 32 | – | – | 2 | |
HJ5209S | – | – | 16 | 8 | – | 2 | |
HJ5209D | – | – | 8 | – | 8 Channel 3-wire PT100 | 2 | |
HJ5209P16 | – | – | – | – | 16 Channel 3-wire PT100 | 2 | |
HJ5209K16 | – | – | – | – | 16 Channel thermocouples | 2 |
PLC Profinet Remote I/O Module Manual
Does PROFINET distributed IO support 200SMART?
The new 200SMART supports PROFINET communication if the PLC version is in version 2.3
The following firmware needs to be upgraded, and PROFINET can be supported after the upgrade. At the same time S7
The program software also requires 2.4 or above.
How many PROFINET distributed IOs can Siemens PLC connect?
In addition to the sub-station module that Siemens PLC owns, 200SMART can support 8 PROFINET distributed IO modules,
Siemens 1200 can support 16 PROFINET distributed IO modules,
Siemens 1500 can support 128 PROFINET distributed I0 modules
PROFINET distributed IO modules have two PN ports, can they be cascaded?
Yes, these two network ports are small switches
What is the use of RS485 interface on the PROFINET distributed IO module?
This 485 is a MODBUS to PROFINET or PROFINET to MODBUS
Gateway, support to connect MODBUS RTU equipment such as current, temperature control meter, inverter and other terminals
device, by configuring MODBUS channel command, register address, generate GSD file guide
Enter into Botu or S7 programming software to automatically generate I address and Q address. Siemens PLC does not
Using the MODBUS program again, you can read and write and control the RTU directly by IW or QW.
What is the LINKTX function?
This is for connecting to expansion modules. After each PROFINET distributed IO module, you can also
Up to 6 expansion modules can be connected. The expansion modules do not occupy the PN site and can expand the digital quantity.
Quantity and temperature.
What is the resolution of the PROFINET distributed 10-module analog?
The analog resolution is one thousandth, and the actual measurement is between five thousandths and one thousandth.
How much current does the PROFINET distributed IO module digital output support?
The digital output is divided into relays and transistors, and supports 2A working current.
Is there isolation for PROFINET distributed 10-module digital quantity?
Digital outputs with optocoupler isolation
Is PROFINET distributed IO module stable?
PROFINET distributed IO modules have been widely used in various industrial occasions, and thousands of projects are running stably.
What is the difference between PROFINET distributed IO module and ET200?
The PROFINET distributed IO module is an integrated module that supports digital and analog temperature, etc. It can be used as a PN slave independently without a gateway, and can replace ET200. ET200 itself does not have IO, need to add sub-station module
Does PROFINET distributed IO module support other controllers?
As long as it can be used as a PROFINET master controller, it can be compatible. At present, KUKA has been tested and ABB Robotics.
What is the range of analog and temperature?
Current signal 0-20MA range is 0-20000; 4-20MA range is 4000-20000;
Voltage signal 0-10V range is 0-10000
The data collected by the temperature module PT100/PT1000 thermal resistance divided by 50 is the actual temperature
The data collected by the temperature module K-type thermocouple divided by 10 is the actual temperature.
What is the maximum distance of the network cable?
The standard Category 6 cable can reach 100 meters, and if a single-core fiber is used, it can reach several hundred meters and a few kilometers.
inside.
评论
发表评论