Ethernet Communication Module for Mitsubishi A series PLC

 

Ethernet Communication Module for Mitsubishi A series PLC Programming Adapter replace USB-SC09, Modbus TCP Gateway KepWare OPC

(The  PLC in the pictures are NOT included,  V2.0 adapter includes two MD8 to DB25 cables.)

Features:
   1. Installed on the 35mm rail, the COM1 port is directly connected to the PLC programming communication port. BCNet-A requires an external 24VDC power supply.
    2, Integrated WEB server, through the web page can set device parameters and run diagnostics, and set the login protection password to prevent tampering with configuration data.
    3. Adaptation of Mitsubishi PLC programming port communication parameters, no additional settings are required.
    4. Integrated ModbusTCP server, supporting FC1, FC2, FC3, FC5, FC6, FC16, Modbus data area is automatically mapped to the data area of Mitsubishi PLC.
    5, using ModbusTCP mode, can achieve high-level language (such as VB, VC, C#, etc.) programming, to achieve data communication with Mitsubishi PLC, to facilitate the development of production management systems.
    6. SCADA (upper configuration software) supporting OPC channel communicates with Mitsubishi PLC in OPC mode.
    7. Support up to 6 PCs to collect PLC data at the same time.
    8. Support firmware update via Ethernet,
Ethernet-Communication-Module-for-Mitsubishi-A-series-PLC-Programming-Adapter-replace-USB-SC09-Modbus-TCP-Gateway-KepWare-OPC-2251832850772581Ethernet-Communication-Module-for-Mitsubishi-A-series-PLC-Programming-Adapter-replace-USB-SC09-Modbus-TCP-Gateway-KepWare-OPC-2251832850772581Ethernet-Communication-Module-for-Mitsubishi-A-series-PLC-Programming-Adapter-replace-USB-SC09-Modbus-TCP-Gateway-KepWare-OPC-2251832850772581

Ethernet-Communication-Module-for-Mitsubishi-A-series-PLC-Programming-Adapter-replace-USB-SC09-Modbus-TCP-Gateway-KepWare-OPC-2251832850772581

Typical application:

1.  SCADA Ethernet monitoring (Kingwang, MCGS, Force Control, WinCC, KepWare OPC), device networking.

   Ethernet-Communication-Module-for-Mitsubishi-A-series-PLC-Programming-Adapter-replace-USB-SC09-Modbus-TCP-Gateway-KepWare-OPC-2251832850772581

2. Support HMI software such as Kingview, MCGS, Force Control, WinCC, KepWare OPC to collect data in ModbusTCP mode. Take the ModScan32 test as an example.

(1) Run the ModScan32 software.

(2) Select the menu Connection/Connect, select Remote TCP/IP Server, enter the IP address of BCNet-A, and the service port is 502; click the [OK] button as shown.

Ethernet-Communication-Module-for-Mitsubishi-A-series-PLC-Programming-Adapter-replace-USB-SC09-Modbus-TCP-Gateway-KepWare-OPC-2251832850772581

 

(3) In the sub-window "ModSca1", set the Device ID to the station address of the PLC (such as 1), and select the function number 03:HOLDING REGISTER, Address = 20001, Length = 100.

(4) The sub-window data area displays the hexadecimal data of 420001 to 420100, which corresponds to the values of the registers D0 to D99 of the Mitsubishi A-series PLC, as shown in the figure.

Ethernet-Communication-Module-for-Mitsubishi-A-series-PLC-Programming-Adapter-replace-USB-SC09-Modbus-TCP-Gateway-KepWare-OPC-2251832850772581

 

(5) Double-click the data in the data area of the sub-window to modify the value.

 

Technical Parameters:

 